Isolator 8000

This series of modules is compact and conforms to the internationally standard DIN rail mounting format, offering an exceptionally high performance‑to‑price ratio. Built using advanced SMD technology, they deliver highly reliable and stable operation, making them an ideal interface unit for smart controllers and DCS systems.



Business Inquiry:+86-15617410151

E-mail:848665210@qq.com


Product Overview


Overview of the HXWP8000 Series Miniaturized Multifunctional Distributors, Isolators, and Temperature Transmitters

This series of modules is compact and conforms to the internationally standard DIN rail mounting format, offering an exceptionally high performance‑to‑price ratio. Built using advanced SMD technology, they deliver highly reliable and stable operation, making them an ideal interface unit for smart controllers and DCS systems.

General Technical Conditions

Accuracy ±0.5%F·S Dielectric strength Between input, output, and the power supply: AC 1500 V / 1 minute
Linear ±0.1%F·S Insulation resistance Between input, output, and power supply: 100 MΩ (DC 500 V)
Load resistance 250–750 Ω Consumptive utilitarianism 1.5 W (one channel)
Temperature coefficient <100 ppm/°C Power supply DC 2.4 V ±10%
Response time <0.1S (0–9%) Operating temperature 0 -4 0℃<9 5%RH

Model and Specifications

Name Specifications and Model Number Input signal Output signal Function
Distributor (one input, one output) HXWP-8047 4–20 mA DC 4–20 mA DC or 1–5 V DC It supplies power to two-wire transmitters and isolates and converts the transmitter’s signal for output. Note: Both input and output signal types can be customized.
Distribution unit (one input, two outputs) HXWP-8035 4–20 mA DC 4–20 mA DC or 1–5 V DC (dual-channel isolated output)
Distributor/Isolator (One Input, One Output) HXWP-8039 4–20 mA DC 4–20 mA DC or 1–5 V DC
Distributor/Isolator (One Input, Two Outputs) HXWP-8069 4–20 mA DC 4–20 mA DC or 1–5 V DC (dual-channel isolated output)
Isolator (one input, one output) HXWP-8067 4–20 mA DC 4–20 mA DC or 1–5 V DC Input and output signal isolation conversion. Note: Both input and output signal types can be customized.
Isolator (one input, two outputs) HXWP-8034 4–20 mA DC 4–20 mA DC or 1–5 V DC (dual-channel isolated output)
Thermocouple transmitter (one input, one output) HXWP-8081 Thermocouple (Single-Channel Input) 4–20 mA DC or 1–5 V DC

Isolate and convert the sensor’s temperature signal into an output.

Note: Both input and output signal types can be customized.

Thermocouple transmitter (one input, two outputs) HXWP-8082 Thermocouple (Single-Channel Input) 4–20 mA DC or 1–5 V DC (dual-channel isolated output)
Resistance temperature transmitter (one input, one output) HXWP-8083 Resistance thermometer (single-channel input) 4–20 mA DC or 1–5 V DC
Resistance Temperature Detector Transmitter (One Input, Two Outputs) HXWP-8084 Resistance thermometer (single-channel input) 4–20 mA DC or 1–5 V DC (dual-channel isolated output)

Working principle

The HXWP8000 series transmitter power supply is a compact, card‑mounted instrument. Its primary function is to provide an isolated power supply to field‑mounted two‑wire transmitters via a DC‑DC converter, while simultaneously converting the 4–20 mA DC signals from these transmitters into isolated 1–5 V DC or 4–20 mA DC signals for use by indicators, recorders, analog controllers, and DCS systems. It is widely employed in industrial process measurement and control systems. Consequently, this power supply is an indispensable component in non‑explosion‑proof automatic control systems.

The HXWP8000 series isolator is a compact, card‑mounted instrument whose primary function is to convert 4–20 mA DC or 1–5 V DC signals into mutually isolated 4–20 mA DC or 1–5 V DC outputs, which can be supplied to indicators, recorders, analog controllers, programmable single‑ or multi‑loop digital controllers, distributed control systems, and industrial process control computers, thereby forming a wide variety of automatic monitoring and control systems. Consequently, this isolator is an indispensable instrument for constructing non‑explosion‑proof automatic control systems.

Features

Input, power supply, and output are electrically isolated from one another.

Input Overcurrent Protection

Dynamic response time is less than 0.1 s.

Wiring Diagram

Installation method and mounting dimensions (using a standard DIN rail)

Usage and Maintenance

1. Before use, the instrument must be calibrated; only after confirming that it is functioning properly may it be put into service. Note that for a 1–5 VDC output, the internal resistance is ≥250 kΩ, while for a 4–20 mA DC output, the internal resistance ranges from 250 to 750 Ω.

2. During normal operation, the instrument requires no special maintenance; only periodic inspections are necessary.

3. If the instrument malfunctions, it must be repaired. During maintenance, simply verify that the supply voltage is 24 VDC and that the distribution voltage is between 18.5 and 28.5 VDC. Otherwise, please return the instrument to the manufacturer for repair.

Ordering Instructions

When placing your order, please specify the product name, model and specifications, and quantity. (If 220V AC power is required, please indicate this at the time of ordering.)

 

关键词: Isolator 8000

Online Inquiry

If you are interested in our services, please fill out the form below, and we will contact you as soon as possible.

Related products

Recommended products


Liquid Crystal Flow Totalizer

Flashing alarm

Isolator, black terminal

It converts various DC current signals into the required DC signals, achieves direct electrical isolation between signals, eliminates ground loops and reduces interference, and also provides high-voltage protection and surge suppression.

Isolator 8000

This series of modules is compact and conforms to the internationally standard DIN rail mounting format, offering an exceptionally high performance‑to‑price ratio. Built using advanced SMD technology, they deliver highly reliable and stable operation, making them an ideal interface unit for smart controllers and DCS systems.